a1055

CONDUCTOR: Stranded tinned copper.
INSULATION: PVC or PVC/nylon.
COLOR: See Color Code Chart No. 6

USES: This wire is intended for use as a general purpose hook-up wire for electronic equipment operating over a temperature range of -55° C to 105° C. The temperature rating may be exceeded approximately 10° C when the wire is covered with a nylon jacket per MIL-DTL-16878.

Catalog No. AWG Size Stranding Type Weight Color Code
502-110 8 133/29 MIL-DTL-16878/3 Type D 73.8 lbs/1000 ft
110 kgs/km
Chart 6
502-110AB 8 133/29 MIL-DTL-16878/19 Type D/N 77.7 lbs/1000 ft
116 kgs/km
Chart 6
502-121 6 133/27 MIL-DTL-16878/3 Type D 101 lbs/1000 ft
151 kgs/km
Chart 6
502-121AB 6 133/27 MIL-DTL-16878/19 Type D/N 106 lbs/1000 ft
157 kgs/km
Chart 6
502-132 4 133/25 MIL-DTL-16878/3 Type D 161 lbs/1000 ft
239 kgs/km
Chart 6
502-132AB 4 133/25 MIL-DTL-16878/19 Type D/N 165 lbs/1000 ft
245 kgs/km
Chart 6
502-143 2 133/23 MIL-DTL-16878/3 Type D 250 lbs/1000 ft
371 kgs/km
Chart 6
502-143AB 2 133/23 MIL-DTL-16878/19 Type D/N 257 lbs/1000 ft
383 kgs/km
Chart 6
502-154 1 259/25 MIL-DTL-16878/3 Type D 316 lbs/1000 ft
470 kgs/km
Chart 6
502-154AB 1 259/25 MIL-DTL-16878/19 Type D/N 325 lbs/1000 ft
484 kgs/km
Chart 6
502-165 1/0 259/24 MIL-DTL-16878/3 Type D 418 lbs/1000 ft
622 kgs/km
Chart 6
502-165AB 1/0 259/24 MIL-DTL-16878/19 Type D/N 431 lbs/1000 ft
641 kgs/km
Chart 6
502-22 24 7/32 MIL-DTL-16878/3 Type D 4.69 lbs/1000 ft
6.98 kgs/km
Chart 6
502-22A 24 19/36 MIL-DTL-16878/3 Type D 4.82 lbs/1000 ft
7.17 kgs/km
Chart 6
502-22AA 24 7/32 MIL-DTL-16878/19 Type D/N 5.46 lbs/1000 ft
8.12 kgs/km
Chart 6
502-22AB 24 19/36 MIL-DTL-16878/19 Type D/N 5.59 lbs/1000 ft
8.32 kgs/km
Chart 6
502-33 22 7/30 MIL-DTL-16878/3 Type D 5.97 lbs/1000 ft
8.88 kgs/km
Chart 6
502-33A 22 19/34 MIL-DTL-16878/3 Type D 6.10 lbs/1000 ft
9.08 kgs/km
Chart 6
502-33AA 22 7/30 MIL-DTL-16878/19 Type D/N 6.74 lbs/1000 ft
10.0 kgs/km
Chart 6
502-33AB 22 19/34 MIL-DTL-16878/19 Type D/N 6.87 lbs/1000 ft
10.2 kgs/km
Chart 6
502-44 20 7/28 MIL-DTL-16878/3 Type D 7.53 lbs/1000 ft
11.2 kgs/km
Chart 6
502-44A 20 19/32 MIL-DTL-16878/3 Type D 7.75 lbs/1000 ft
11.5 kgs/km
Chart 6
502-44AA 20 7/28 MIL-DTL-16878/19 Type D/N 8.05 lbs/1000 ft
12.0 kgs/km
Chart 6
502-44AB 20 19/32 MIL-DTL-16878/19 Type D/N 8.26 lbs/1000 ft
12.3 kgs/km
Chart 6
502-55A 18 19/30 MIL-DTL-16878/3 Type D 9.87 lbs/1000 ft
14.7 kgs/km
Chart 6
502-55AB 18 19/30 MIL-DTL-16878/19 Type D/N 10.6 lbs/1000 ft
15.8 kgs/km
Chart 6
502-66 16 19/29 MIL-DTL-16878/3 Type D 12.1 lbs/1000 ft
17.9 kgs/km
Chart 6
502-66AB 16 19/29 MIL-DTL-16878/19 Type D/N 12.8 lbs/1000 ft
19.1 kgs/km
Chart 6
502-77 14 19/27 MIL-DTL-16878/3 Type D 17.3 lbs/1000 ft
25.7 kgs/km
Chart 6
502-77AB 14 19/27 MIL-DTL-16878/19 Type D/N 18.3 lbs/1000 ft
27.2 kgs/km
Chart 6
502-88 12 19/25 MIL-DTL-16878/3 Type D 27.1 lbs/1000 ft
40.3 kgs/km
Chart 6
502-88AB 12 19/25 MIL-DTL-16878/19 Type D/N 28.5 lbs/1000 ft
42.4 kgs/km
Chart 6
502-99 10 37/26 MIL-DTL-16878/3 Type D 39.3 lbs/1000 ft
58.5 kgs/km
Chart 6
502-99AB 10 37/26 MIL-DTL-16878/19 Type D/N 41.8 lbs/1000 ft
62.2 kgs/km
Chart 6