All Categories > Mil Spec Products > Class H Shielded & Jacketed Type E Cables > Three Conductor MIL-W-16878/4 > View Items  
    Printable Page     Email Email This Page     Save To Favorites Save To Favorites

Three Conductor MIL-W-16878/4

Check up to five results to perform an action.

CONDUCTOR: Stranded silver-plated or nickel-plated copper. JACKET: Extruded FEP or wrapped PTFE with 0.008" / 0.012" wall thickness. Saturated glass fiber braid jackets are also available. CONSTRUCTION: Dielectric is PTFE with 0.008" /0.012" wall thickness. Cable twisting 1.5 to 2.5 inch lay. Shield is silver-plated or nickel-plated copper, 90% minimum coverage.

SPECIFICATION: The individually insulated conductors are manufactured to meet the requirements of MIL-W-16878/4 Type E. These cables can also be manufactured to MIL-C-55021 & MIL-DTL-27500 upon request. Also available with MIL-W-16878/5 Type EE and MIL-W-16878/6 Type ET conductors.

COLOR: Primary conductors are color coded per the requirements of MIL-C-915. Custom color coding per your requirement is available upon request. All colors remain fast on continuous exposure to light, heat, or solvents, and conform to MIL-STD-104. Primary insulation (dielectric) with wrapped PTFE jackets or extruded FEP jackets are available in the following colors: Black, brown, red, orange, yellow, green, blue, purple, gray, and white.

USES: When temperature requirements range from -65° C to 260° C at 600 volt RMS maximum (silver-plated: -65° C to 200° C; nickel-plated: -65° C to 260° C.)

The Letter in Catalog No. Indicates:
E = Wrapped PTFE jacket.
F = Extruded FEP jacket.

All dimensions are nominal.




Compare Items
   
  Results 1 - 16 of 16 1 

Catalog No.

AWG Size

Stranding

Conductor O.D.

Insulation O.D.

Shield O.D.

Jacket O.D.

Weight

1100-22S 30 7/38 0.012 in
0.30
mm
0.032 in
0.81
mm
0.092 in
2.34
mm
0.114 in
2.90
mm
10.5 lbs/1000 ft
15.6
kgs/km
1100-22T 30 7/38 0.012 in
0.30
mm
0.032 in
0.81
mm
0.092 in
2.34
mm
0.114 in
2.90
mm
10.5 lbs/1000 ft
15.6
kgs/km
1100-33S 28 7/36 0.015 in
0.38
mm
0.035 in
0.89
mm
0.098 in
2.49
mm
0.120 in
3.05
mm
11.8 lbs/1000 ft
17.6
kgs/km
1100-33T 28 7/36 0.015 in
0.38
mm
0.035 in
0.89
mm
0.098 in
2.49
mm
0.120 in
3.05
mm
11.8 lbs/1000 ft
17.6
kgs/km
1100-44S 26 19/38 0.019 in
0.48
mm
0.039 in
0.99
mm
0.107 in
2.72
mm
0.129 in
3.28
mm
14.8 lbs/1000 ft
22.0
kgs/km
1100-44T 26 19/38 0.019 in
0.48
mm
0.039 in
0.99
mm
0.107 in
2.72
mm
0.129 in
3.28
mm
14.8 lbs/1000 ft
22.0
kgs/km
1100-55S 24 19/36 0.025 in
0.64
mm
0.045 in
1.14
mm
0.119 in
3.02
mm
0.135 in
3.43
mm
17.3 lbs/1000 ft
25.7
kgs/km
1100-55T 24 19/36 0.025 in
0.64
mm
0.045 in
1.14
mm
0.119 in
3.02
mm
0.135 in
3.43
mm
17.3 lbs/1000 ft
25.7
kgs/km
1100-66S 22 19/34 0.031 in
0.79
mm
0.051 in
1.30
mm
0.132 in
3.35
mm
0.148 in
3.76
mm
21.6 lbs/1000 ft
32.1
kgs/km
1100-66T 22 19/34 0.031 in
0.79
mm
0.051 in
1.30
mm
0.132 in
3.35
mm
0.148 in
3.76
mm
21.6 lbs/1000 ft
32.1
kgs/km
1100-77S 20 19/32 0.040 in
1.02
mm
0.060 in
1.52
mm
0.151 in
3.84
mm
0.167 in
4.24
mm
28.2 lbs/1000 ft
42.0
kgs/km
1100-77T 20 19/32 0.040 in
1.02
mm
0.060 in
1.52
mm
0.151 in
3.84
mm
0.167 in
4.24
mm
28.2 lbs/1000 ft
42.0
kgs/km
1100-88S 18 19/30 0.050 in
1.27
mm
0.070 in
1.78
mm
0.173 in
4.39
mm
0.189 in
4.80
mm
37.7 lbs/1000 ft
56.1
kgs/km
1100-88T 18 19/30 0.050 in
1.27
mm
0.070 in
1.78
mm
0.173 in
4.39
mm
0.189 in
4.80
mm
37.7 lbs/1000 ft
56.1
kgs/km
1100-99S 16 19/29 0.057 in
1.45
mm
0.080 in
2.03
mm
0.195 in
4.95
mm
0.213 in
5.41
mm
46.1 lbs/1000 ft
68.6
kgs/km
1100-99T 16 19/29 0.057 in
1.45
mm
0.080 in
2.03
mm
0.195 in
4.95
mm
0.213 in
5.41
mm
46.1 lbs/1000 ft
68.6
kgs/km
  Results 1 - 16 of 16 1 

 

Site created by ThomasNet Web Solutions, a division of ThomasNet.com
Toll-Free: 800.326.0006The Electronic Wire and Cable Specialist for Over 60 Years